Q-Series
®
Optical – QFOT1310 Series Broadcast Transmitter – Installation & Operation Manual 9-1
CHAPTER 9: CLEANING & MAINTENANCE
CLEANING & MAINTENANCE
9. Cleaning & Maintenance
Each ber connector can become contaminated by dust or dirt in the operation process, which can result in increased optical
link loss, or a degraded carrier-to-noise ratio. If you nd that the optical receiver power or RF output level of the optical
receiver has declined, you should clean and maintain the ber active connector. The cleaning methods are recommended
below:
a) Carefully unplug or unscrew the active ber connector from the adapter, while being careful to avoid aiming the ber
connector at any human body or eye.
b) Use a lint-free ber optic wipe saturated with alcohol to clean the connector carefully. Once nished, still wait 1-2
minutes until active connector surface is dry in the air.
c) When the cleaned optical active connector is reconnected to the adapter, please do not over-tighten or force the
connector, to avoid damage to the ceramic ferrule.
d) The ber active connector should be cleaned on both ends. If optical power is still low after cleaning, clean the other
end of the ber. If the optical power is still low after cleaning both ends, it is recommended that you clean the inner
adaptor. (Take care of the ber when disassembling the adaptor).
e) Use compressed air or a lint-free wipe to wash the adapter carefully. When using compressed air, aim the nozzle at
the ceramic ferrule of the adaptor to clean.
NOTE:
1. Avoid aiming the optical output or ber connector at the human body or eyes.
2. Assemble the ber adaptor gently and carefully to prevent damage to the ceramic ferrule inside the adapter.
CHAPTER 8: SNMP MANAGEMENT